Take the next step.

Request a quote for our quality-assured and sampling services, and we will get back to you in the next couple of business days.

Get in touch with us.

Have questions or comments about our services? Please send us a message and we will get in touch with you soon.

CONTACT US

Analysis of SVOC in stack emission samples

Sampling & analysis of SVOC in stack emission sample

Over the past century industries have discharged considerable quantities of gas containing SVOC into the environment. As a result, elevated levels of these compounds are found, not only locally, but at distant locations due to long range transport.

Analytical method & sampling procedure

ALS environmental offers a full range of accredited analytical procedures for stationary source emissions based on US EPA, ISO or EN methodologies. Our laboratories will also provide the appropriate sampling media and solutions.

The analytical procedure follows international standards and methods.


Example of compounds, group of compounds or methods provided

AIR TOXIC SERVICES
Analytes Reference
Dioxins (PCDD/F) EN 1948,2-3; US EPA 23; US EPA TO9A
PCB EN 1948,4; JIS K 0311
PAH US EPA 429; ISO 11338
PBDE Modified US EPA 1614
Phenol EN ISO 14402

POLYCHLORINATED DIBENZO-P-DIOXINS AND POLYCHLORINATED DIBENZOFURANS (PCDD/F)

Samples are collected through a PUF or XAD trap module, sometimes with liquid impingers (glycols). The sorbent (XAD-2 or PUF, glycol) is then extracted by organic solvents, precleaned by multiplied column chromatographies, and the final extract is analysed by HRGC-HRMS. The method is optimized for the 17 most toxic PCDD/F congeners and for chlorohomologue groups from tetra- to octa- CDDs and CDFs (All 210 chlorinated dioxins and furans).


POLYCHLORINATED BIPHENYLS (PCB)

Samples are collected through PUF or XAD trap module. The sorbent (XAD-2 or PUF) is then extracted by organic solvents, precleaned by multiplied column chromatographies, and the final extract is analysed by HRGC-HRMS. The method is optimised for indicator PCBs (PCB-7), coplanar PCBs (dioxin-like PCBs) and for chlorohomologue groups from mono- to deca- chlorinated biphenyls (All 209 PCBs).


POLYAROMATIC HYDROCARBONS (PAH)

Samples are collected through PUF or XAD trap module. The sorbent (XAD-2 or PUF) is then extracted by organic solvents, pre-cleaned by multiplied column chromatographies, and the final extract is analysed by HPLC or by HRGC-HRMS.


PHENOL FROM STATIONARY SOURCES

Samples are collected by bubbling air through a sodium carbonates (Na2CO3) solution. Samples are analysed by photometry by reaction with 4-aminoantipyrine.

Related services

Analysis of inorganic compounds in stack emission samples.

Inorganic compounds is frequently found in emissions. Many of these compounds can have a negative impact on the environment

MORE INFORMATION

Analysis of heavy metals including mercury and hexavalent chromium

Heavy metals in emission from factories present a risk to the environment and human health

MORE INFORMATION

Analysis of VOC in stack and emission samples

Emission of volatile organic compounds needs to be monitored in stack and emission samples due to the potential negative impact on the surroundings.

MORE INFORMATION