EnviroMail 04 USA
Maximizing Quality, Field Sampling Efficiency and Safety for Metals Water Sampling (Excluding Mercury)
Sampling for trace metals in groundwaters, surface waters, leachates and process waters is one of the most common field techniques utilized across the environmental industry globally.
There are several practices used in different regions and this EnviroMail discusses changes at ALS in support of global best practice. This is the first of two EnviroMails that will provide background information and technical guidance on trace metal preservation and sampling, along with changes being introduced by ALS to help maximize quality, safety, and efficiency in the field. The second EnviroMail due for release next month will look at the importance of field filtration and the impacts this can have on data quality.
One of the most crucial aspects of trace metals analysis is the quality of the sample container. Producing bottles devoid of metals requires excellent controls and the right grade of plastics. It is well known that some grades of plastics leach trace amounts of metals over time, when exposed to acids or acid preserved water, even if cleaned. This may be immaterial to some applications but not when testing metals at trace levels. Sourcing the right bottles is important to ensure data integrity. The new metals sample bottles adopted by ALS are custom-designed and manufactured specifically for ALS by a major global scientific company. They are produced in a dust-free environment using high grade plastic with stringent controls to ensure that releasing agents used in bottle production do not impact trace metals analysis. These bottles are then sealed in plastic bags and boxed and tested to levels below reporting detection limits using rigorous procedures to ensure the highest standards — a process that has been used by ALS overseas for several years to produce and proof in excess of 1.7 million bottles.
The practice of pre-rinsing a bottle with sample is largely an outdated practice from decades past when sample bottles were washed and reused by laboratories. Under those conditions, good field practice was to pre-rinse the bottle with sample prior to filling. In other field applications, auto-sampler bottles were also re-used, adding to the need for this ‘rinse with sample step’. This is no longer recommended, as bottles provided by ALS meet strict quality requirements without additional handling or cleaning in the field. It is important to ensure that all field sampling equipment is suitable and free of trace metals contaminants. Pre-rinsing of bottles cannot be performed where bottles are pre-charged with acid preservative.
Recently, many ALS USA laboratories have adopted the ALS global standard 60 mL sample bottles for collection of total and dissolved metals (reduced from 250 mL or 500 mL bottles previously provided). The ALS technical team has facilitated meeting all current detection limits using these smaller sample containers to the benefit of our clients. This will see ALS customers needing to sample or field filter only a fraction of the sample that was previously required, which is the result of best practice technology sharing across our global network of laboratories. Benefits to ALS clients include:
- Reduced time for sample collection and filtration which reduces field costs;
- A small part in a global push to reduce HSE risks associated with handling heavy coolers. Ten water samples for metals now weighs 0.6 to 1.9 kg less, which contributes to lower manual handling risks;
- Smaller bottles are beneficial for low flow sampling or low recharge wells, saving considerable field time on groundwater sampling;
- Smaller bottles can reduce multiple bailing events. Even more important is the use of the first bailer collected for filtering of dissolved metals, as it is typically less disturbed, containing less fine sediment or colloids that may pass through filters, impacting results.
Other Quality Benefits
One of the biggest risks of metals false positives in groundwater sampling on windy days is contamination by dust during field filtration or sampling. The new smaller ALS bottles cut filtration time dramatically and the removal of acid vials allows the bottle cap to be replaced more quickly which through a lower time exposure also reduces the risk of false positives by airborne dust.Pre-charged Nitric Acid Metals Preservative Bottles
It is very important that dissolved metals samples be filtered in the field prior to acid-preservation, otherwise metals will leach from any entrained sediment, which can cause substantially elevated metals concentrations. The key here is that when needing to filter only 60 mL (or 125 mL) of sample, a single syringe filter usually suffices, and best practice in metals sampling is achieved with reduced risk of false positives or negatives. The addition of the water sample to the pre-charged bottle does not pose risk from exothermic heat generation due to the very small quantity of dilute acid used as the preservative agent relative to the volume of water. Benefits to field staff over and above benefits of the smaller bottles include:
- These bottles can be used for rush turnaround as required
- Simpler, faster, easier, field sampling processes; reduces field sampling costs
- Samples may be submitted to the lab for analysis anytime within the 6-month holding time
New! Lab Preserved Metals Option - Eliminates Handling of Nitric Acid in the Field
Complementing the new ALS 60 mL (or 125 mL) metals sample bottles, ALS is also introducing a new, convenient Lab Preservation option for total and dissolved metals that completely eliminates the use of nitric acid preservatives in the field. A survey of industry customers indicated unanimous support for this option already in use by ALS overseas, and as a result this practice is being introduced in the USA. This new option is recommended by the US EPA and is available at most ALS laboratories. Field sampling practices remain relatively unchanged, and samplers simply collect filtered or un-filtered water samples into the bottles provided, and ensure samples are shipped to the lab within 10 days of sampling. Dissolved Metals samples must be field filtered, which is recognized as the best practice for field sampling to ensure optimal data quality. Samples will be preserved at the laboratory with nitric acid (within 14 days of sampling). After lab preservation, samples must be equilibrated for at least 16 hours prior to analysis, so this option is not suitable for same day or next day analysis requirements, however any rapid turnaround samples can be collected and submitted using pre-charged bottles (see earlier). Normal turnaround times will remain unaffected. Holding times are extended to six-months after lab preservation. Benefits to clients include:
- Reduction of safety risks associated with handling nitric acid in the field
- Simpler, faster, easier, field sampling processes – improving efficiency
- Sample bottle is compatible with field sampling apparatus that require submerging of sample containers
- Available for all routine and ultra-trace metals packages (acid cleaned bottles are required for some ultra-trace metals packages)
- No impacts to data quality (recommended as best practice by the US EPA)
Please contact your ALS Project Manager or technical support staff for further information on these changes, or with any questions that you may have.