Turbine oil is required to support journal and thrust bearings under moderate and heavy loads and elevated temperatures with an oil film that is thinner than a human hair. The oil in these systems is expected to provide trouble free service life for 5 to 15 years, depending on the system. Cleanliness and good oxidation resistance is critical to the performance of these lubricants
The three types of industrial application turbine power systems (non-aviation) are gas, steam, and hydroelectric. Systems can vary in size and design, reservoir configuration, and rotational speeds that affect the life and performance requirements of the lubricants in service. Turbine oils are expected to lubricate and protect components such as journal and thrust bearings, gears and gear drives. They are also required to provide power in directional and hydraulic controls components, such as governors, control valves, and safety devices. Cooling of lubricated parts is also an essential function of in-service turbine oils.
Type | Shaft Speed, rpm | Oil Temperature, C (F) | Oil Service Life, Years |
Gas | 3,000-9,000 | 55-95 (130-200) | 3-5 |
Steam | 1,000-20,000 | 45-70 (110-160) | 10+ |
Hydroelectric | 75-900 | 45-70 (110-160) | 10+ |
Turbine lubrication systems should be inspected on a regular basis. Testing should be performed according to a routine or monthly schedule, quarterly schedule, and annual schedule. Routine testing can inspect for lubricant cleanliness, contaminants, and general product integrity, as well as component wear. Quarterly and annual testing will look at oxidative and service life performance, varnish potential in the system, as well as routine tests for cleanliness, contaminants, general product integrity, and component wear.
Routine monitoring should also include a check list of visual inspections that are to be performed. This can include the reservoir, oil purification components (filters, centrifuge), seals, leaking fittings, water drains, and sight glass. Noting the smell of turbine oil can also detect possible contamination or degradation of the oil. If the oil has a distinct sulfur (rotten egg) smell, it can be an indication of microbial contamination in the system. If the odor becomes pungent or sour smelling, it could be an indication of overheating from the oil cracking due to excessively high operating temperatures. Some testing specific to turbine application and design can be performed as needed or included in an inspection schedule. Water separability and rust inhibitor performance in steam and hydroelectric systems should be periodically measured. Because of the nature of the severe service environment in gas turbine systems due to high temperatures and mixture with exhaust gases, monitoring oxidation and varnish potential is critical. Testing for foaming tendency may be required if excessive foaming occurs due to system design or contaminants in the fluid.Written By: